Support for Instructors Part I

Part I Essentials

Figures that are new in the 4th edition are marked with a NEW tag.

Chapter 1

Fig. 1.4 The many facets of mass spectrometry. Each aspect is closely related to the others in
various ways. Their assemblage yields an impression of the dimensions of MS.

Fig. 1.6 General layout of mass spectrometers. Several types of sample inlets can be attached to the ion source housing. Transfer of the sample from atmospheric pressure into the high vacuum of the ion source and mass analyzer is accomplished by use of a vacuum lock.

Fig. 1.8 Statistical nature of mass spectra and the appearance of methane spectra based on very low numbers of ions. (a) and (b) by one ion, (c) by eight ions, (d) by eleven ions, (e) by 23 ions, and (f) by thousands. The isotope peak of 1.1% relative intensity at m/z 17 is only visible and meaningful in the case of (f).

Chapter 3

Fig. 3.19 Guideline for the identification of contributing elements based on isotopic pattern
analysis.

Fig. 3.28 Number of possible even-electron ionic formulas based on a free selection among the elements C, H, N, O as a function of relative mass error vs. m/z. The data points correspond to [(arginine)1–5 + H]+ cluster ions, m/z 175.1189, 349.2309, 523.3427, 697.4548, and 871.5666.

Chapter 4

Fig. 4.2 EI/CI/FAB combination ion source of a JEOL JMS-700 sector instrument.

Fig. 4.4 NEW Filaments for EI/CI ion sources. A straight wire filament of the JEOL JMS-700 magentic sector instrument (left) and a vertically coiled filament of the JEOL AccuTOF series (right). The shields behind the filament are at the same potential as the wire itself and the white parts are made of ceramics for insulation.

Fig. 4.5 NEW The EI source of the JEOL AccuTOF GCx mass spectrometer can be observed through the glass cover from the top. In a) the filament is still turned off, in b) the filament is operated as to deliver 100 µA of emission current. The light emission due to heating of the filament to a bright yellow glow can clearly be seen in the middle left part of b). The lens stack to focus the ion beam is visible at the top middle of each photograph

Fig. 4.8 An EI source mounted in the ion source housing of a JEOL AccuTOF GCx instrument. All voltages for operation are supplied via vacuum lead throughs from the left side. A connector to a gas chromatograph reaches down from the upper right while a connector to the reservoir inlet enters from the lower right side. The turbomolecular pump of the ion source housing is located directly below the protective wire mesh on the bottom.

Fig. 4.9 Reservoir inlet of a JEOL JMS-700 sector instrument with the septum injection port opened. The “operation valve” switches between evacuation, isolation, and admission of the sample; a needle valve allows regulation of the sample flow. The GC transfer line crosses in the upper background from the GC (left) to the ion source housing (upper right).

Fig. 4.10 Direct insertion probe (DIP) for use with EI, chemical ionization (CI), and field ionization (FI). a) The copper probe tip holds the glass sample vial and is fitted to a temperature-controlled heater. The heater, a thermocouple, and cooling are provided inside. The (white) ceramics insulator protects the operator from the high voltage of the ion source. b) Entire DIP of a JEOL JMS-700 equipped with water cooling.

Fig. 4.12 A direct insertion probe on a JEOL AccuTOF GCx instrument. The probe is shown in its fully inserted position. The transparent hose (left) provides rough vacuum to the lock before insertion of the probe, the gray cable connection serves for heater power supply and temperature control, and the light brown capillary delivers pressurized gas for cooling the probe tip if required.

Fig. 4.13 Sample vials for different DIPs. From left: VG ZAB-2F, Finnigan TSQ700 glass and aluminum version, and JEOL JMS-700. The match illustrates the scale.

Fig. 4.14 Sample vial loaded with some analyte. The bright yellow speck halfway between the tip of the tweezers and upper rim of the vial is the solid material to be analyzed.

Fig. 4.15 Automated DIP in operation as visualized by multiple exposures. After having received the sample vial in vertical orientation, the rod is driven to the left and tilted downward for insertion through the lock. The photograph shows the SIM DIP mounted to a LECO Pegasus GC-HRT instrument.