Support for Instructors Part II

Part II Instrumentation and Operation

Figures that are new in the 4th edition are marked with a NEW tag.

Chapter 6

Fig. 6.3 NEW Classification of mass analyzers by their principle of operation and resolving power.

Fig. 6.28 NEW Electrostatic sector analyzer of a JEOL JMS-700 double-focusing magnetic sector instrument as seen in its housing after removing the top cover. The massive 90° cylindrical condenser was operated at a DC voltage of about 520 V across the electrodes and positioned after the magnetic sector. Ions would enter through the intermediate slit at the top right and exited to the detector at the bottom left side via the detector slit.

Fig. 6.34 Flight tube passing through the gap of the magnetic sector of a JEOL JMS-700 instrument seen from the ESA side. The shapes of the pole pieces of the yoke and the additional blocks around the tube are designed to minimize fringing fields. In addition the pole faces are rotated to increase the mass range.

Fig. 6.43 Linear quadrupole with hyperbolic rods. a) Head on view showing the cross section of the rods and b) whole device partially revealing the polished inner surfaces.

Fig. 6.46 RF octopole ion guide used to bridge a differential pumping stage of an ESI interface in a Finnigan LCQ instrument. a) Head-on view to show the octopole alignment and b) side view.

Fig. 6.59 Electrodes of the Finnigan LCQ quadrupole ion trap analyzer. a) Ring electrode with symmetrical hyperbolic cross section of the inner walls of the ring. b) One of the pair of hyperbolic end cap electrodes.

Fig. 6.68 a Analyzer maintenance of a QIT; here of the Finnigan LCQ. Complete QIT analyzer mounted onto the top cover plate of the vacuum manifold.

Fig. 6.68 b Analyzer maintenance of a QIT; here of the Finnigan LCQ after taking it apart for cleaning.

Fig. 6.88 NEW Bruker Infinity cell as an example of a commercial ICR cell as viewed from the direction of an excitation electrode. This one had been in operation for more than 18 years. The carefully shaped segments of the trapping plate at the cell entrance are visible in this photograph. The electrodes are gold-plated to avoid oxidation and to reduce contamination during the years of use.

Fig. 6.100 NEW Compilation of the configurations of hybrid instruments. All of these variants either had been commercially available in the past or still are

Fig. 6.109 Discrete dynode electron multipliers. An old-fashioned 16-stage Venetian blind-type SEM clearly showing the resistors and ceramics insulators between the stacking dynodes at its side.

Fig.6.112 NEW Secondary electron multiplier (SEM) with discrete dynodes mounted in the detector housing of a JEOL JMS-700 magnetic sector instrument (right). Electrons are delivered from the conversion dynode (left).

Fig. 6.114 Channeltron multiplier. Ions or electrons from a conversion dynode would enter from the left side. Amplification of secondary electrons occurs down the bent tube.

Fig. 6.117 NEW MCP detector of a JEOL AccuTOF GCx instrument (oaTOF) placed in the holder. This instrument uses a set of two stacked MCPs (Chevron plate, Fig. 6.115). The interference pattern caused by the array of tiny channels makes a colorful appearance

Chapter 7

Fig. 7.1 NEW Comparison of tandem-in-space and tandem-in-time MS. Obviously, higher order MSn can be better realized by tandem-in-time setups, whereas tandem-in-space instrumentation is usually designed for MS2 with MS3 representing already the rare exception.

Fig. 7.2 NEW Operation of hybrids with linear Q as MS1 and their modes of operation in terms of the concepts of tandem-in-space and tandem-in-time MS.

Fig. 7.3 NEW Operation of hybrids with linear Q, QIT, or LIT as MS1 and their modes of operation in terms of the concepts of tandem-in-space and tandem-in-time MS.

Fig. 7.4 NEW Operation of instruments with double focusing magnetic sector analyzers as MS1 and their modes of operation in terms of the concepts of tandem-in-space and tandem-in-time MS. While combinations with Q, QIT, or oaTOF presented the first commercially available hybrid instruments, today they are only of historic interest. The four sector instruments, either of BEBE or EBEB geometry, replaced by those first-generation hybrids were extremely huge instruments.

Chapter 8

Fig. 8.25 NEW Comparison of a) heat map in the 1/K0 versus m/z display format, b) base peak mobilogram revealing 41 components, and c) mass spectrum summed across the entire range. All three plots are based on the same data set as shown in Fig. 8.24 f) and g). Note that the larger 1/K0 values also correspond to large CCS values and to higher m/z of the ions.

Fig.8.26 NEW Positive-ion ESI-TIMS analysis to separate the isomeric sodium adduct ions of saccharose, [S+Na]+, and trehalose, [T+Na]+ (1/K0 range 0.80–0.90, ramp time 500 ms, accumulation 2 ms, pressure 2.66 mbar). a) Heat map in the 1/K0 versus m/z display format showing the isomers aligned vertically, b) base peak mobilogram showing three components, and c) extracted ion mobilogram of m/z 365.1 showing two components. The mass spectra corresponding to components #1, #2, and #3 in b) are displayed in d), e), and f).  

Chapter 9

Fig. 9.1 NEW Separation techniques are intended to deconvolute mixtures, i.e., they cause a temporal spread of sample introduction. This chart shows the common and thus established combinations of separation techniques, ionization methods, and mass analyzers.

Fig. 9.2 NEW High resolution and tandem MS provide additional analytical dimensions, even though resolution is normally not considered as a dimension of its own. a) Transition from LR to HR, b) transition from LR tandem MS to HR tandem MS, c) illustration of the levels LR, HR, and UHR (from left).

Fig. 9.3 NEW Ways of increasing the number of analytical dimensions from 2D to 4D.

Fig. 9.6 Fused-silica capillary column for gas chromatography on a coil of about 20 cm in diameter. The golden color is caused by the outer polyimide coating of the silica capillary.

Fig. 9.7 GC oven for capillary gas chromatography with open front door. The GC column
wound onto a coil is suspended to hang freely in the heated air.

Fig. 9.11 UPLC column. The actual column (right), here shown with the two end caps still in place, is quite small as by comparison to the pencil. This particular column is a Waters BEH C18 reversed phase type of 50 mm length and 2.1 mm inner diameter filled with 1.7-μm-sized particles.

Fig. 9.13 A column thermostat of a Waters Acquity system with two UPLC columns mounted inside. The sample solution first passes a heater cartridge to ensure constant temperature equal to that of the column, then a pre-filter to prevent the column from clogging, and finally enters the UPLC column.